R-22 Refrigerant – 30 lb Cylinder for Existing HVAC Systems
Freon™ 22 (R-22) — Professional 30 lb R-22 service cylinder for existing equipment specifically labeled for R-22. Section 608 purchaser verification is required before fulfillment.
$203.00 Original price was: $203.00.$109.00Current price is: $109.00.
In stock
Guaranteed Safe Checkout
Features & Compatibility
Freon™ 22 (R-22) Refrigerant – 30 lb Cylinder for Existing HVAC Systems
Brand: Freon™ 22 (R-22) Manufacturer: The Chemours Company MPN: D10055692 GTIN/UPC: 686114000473
30 lb R-22 service cylinder for existing equipment specifically labeled for R-22. Sale is restricted to qualified purchasers; certification and order documentation must be verified before fulfillment.
Product Overview
R-22 refrigerant for professional service of existing R-22-labeled air-conditioning, heat-pump and refrigeration equipment.
- Net contents: 30 lb (13.6 kg)
- HCFC refrigerant with ozone-depletion potential
- For legacy system maintenance only; not for new equipment
- Use only with compatible equipment, lubricants and approved recovery procedures
Compliance: Federal purchase restrictions apply. Never intentionally vent refrigerant. Confirm equipment compatibility and all federal, state and local requirements before use.
Technical Specifications
| Refrigerant | R22 |
|---|---|
| Net Contents | 30 lb (13.6 kg) |
| Composition | Chlorodifluoromethane (CHClF2) |
| Boiling Point | -40.8°C |
| Safety Classification | A1 |
| GWP / ODP | GWP 1810; ODP 0.055 |
Common Applications
Main application: Existing R-22 HVAC and refrigeration systems.
Intended for maintenance of existing comfort-cooling, heat-pump and refrigeration equipment whose original nameplate specifies R-22. It should not be selected for new equipment or used to top off a system containing another refrigerant.
Compatibility Information
R-22 systems vary by equipment age, compressor design and lubricant. The technician should confirm the equipment label, existing refrigerant, oil type, service history and condition of the circuit before charging. Any conversion to a different refrigerant requires a documented retrofit procedure.
Professional Service and Charging Notes
Locate and repair leaks before adding refrigerant. Recover the existing charge with approved equipment, evacuate the system as required and charge by the equipment manufacturer’s specified method. Never mix R-22 with substitute blends.
Storage and Handling
- Store the cylinder upright, secured and in a cool, dry, well-ventilated area.
- Protect the cylinder from direct sunlight, excessive heat, physical damage and unauthorized access.
- Keep the valve cap or protective collar in place during storage and transportation.
- Use only tools, hoses, recovery equipment and personal protective equipment rated for this refrigerant and its pressure/safety class.
- Never intentionally vent refrigerant. Recover and manage refrigerant in accordance with applicable federal, state and local rules.
EPA Purchase Verification
Purchaser requirement: EPA Section 608 certification or qualifying employer/resale documentation.
Before fulfillment, Cool Gas Depot must verify the applicable technician certification, employer authorization or resale documentation and retain the required online-sales records. Orders may be placed on hold or cancelled when acceptable documentation is not provided.
Hazardous-Material Shipping
This product is a regulated refrigerant/compressed gas and cannot be shipped as an ordinary parcel. Availability, destination eligibility, carrier acceptance, approved packaging and any required hazardous-material fees must be confirmed before fulfillment. Delivery dates are estimates until the order passes compliance and carrier review.
Shipping, Returns and Cancellations
- Shipping area: United States destinations permitted by the carrier and applicable regulations.
- Shipping charge: Free standard shipping on eligible orders.
- Processing: Normally 1–2 business days after payment, inventory and purchaser-documentation review.
- Estimated delivery: Normally 3–7 business days after dispatch. Hazardous-material routing, weather, remote destinations and carrier controls may extend delivery.
- Returns: Contact Cool Gas Depot within 30 days. Only unopened, unused and factory-sealed cylinders are eligible, subject to authorization and carrier/hazardous-material restrictions. Approved return shipping is provided at no cost. Never send a refrigerant cylinder back without written instructions.
- Cancellations: An order may be cancelled before shipment. After carrier acceptance, the approved return process applies.
Review our Shipping Policy and Returns & Refund Policy before ordering.
Safety Data Sheet and Documentation
This listing is for Freon™ 22 (R-22) refrigerant manufactured by The Chemours Company. The current Safety Data Sheet must match the exact product and cylinder label supplied with the order. Cool Gas Depot does not substitute an SDS from another brand or manufacturer. To request the current SDS before shipment, email support@coolgasdepot.shop and include SKU CGD-R22-30.
Also review our Refrigerant Safety Information and EPA Requirements & Refrigerant Purchase Policy.
Before You Order
- Read the equipment or vehicle label and confirm the exact refrigerant type.
- Confirm the required net quantity, cylinder connection and service-equipment compatibility.
- Review the current Safety Data Sheet and the equipment manufacturer’s service instructions.
- Verify that purchase, possession, installation and use are permitted at the delivery location.
- Arrange installation or service by a properly trained and certified technician.
Important Notice
Refrigerants are not universally interchangeable. Never select a refrigerant only because operating pressures or applications appear similar. Incorrect refrigerant, mixed refrigerant, improper charging or incompatible lubricant can damage equipment, reduce performance and create serious safety hazards. Packaging artwork may change over time, but the supplied product must match the Freon brand, refrigerant specification, manufacturer, and package size identified in this listing. Always rely on the cylinder label and Safety Data Sheet supplied with the product.
Additional information
| Refrigerant Type | R22 |
|---|---|
| Net Contents | 30 lb (13.6 kg) |
| Main Application | Existing R-22 HVAC and refrigeration systems |
| Safety Classification | A1 |
| Manufacturer Part Number | D10055692 |